Almost every practical solenoid number comes from four relationships, and all four are simple enough to check with a multimeter and a caliper. Force falls with the square of the air gap while the gap dominates the magnetic circuit. Ampere-turns sets flux, and flux density is limited by saturation rather than by copper. Copper resistance rises 0.393 % per kelvin, which turns a resistance reading into a winding thermometer accurate to about 2 K.

The value of working from these relationships is that they predict which change is worth making. A 40 mm iron path at a permeability of 1000 behaves like 40 micrometres of extra air, so against a 0.5 mm gap the iron is only 7 % of the reluctance and a better steel moves force by single digits. A tolerance that grows the gap by 0.05 mm moves it by 27 %. Knowing the ratio saves the cost of trying the wrong fix.

These notes are the ones most often quoted, because a relationship with a number attached can be checked rather than believed. Each states where the approximation holds and where it stops: the inverse-square rule fails near contact where saturation sets in, and at large gaps where fringing adds effective pole area.