Selection and specification

Most solenoid problems are decided before the first unit is built, in the gap between what the drawing specifies and what the working conditions actually are. A datasheet force is normally measured cold, at nominal voltage, on a typical sample. Restore the three conditions that get left out and a nominal 10 N can arrive at end of stroke as roughly 3 N.

These notes cover the parameters that decide whether a design holds: force at the working gap rather than at contact, ampere-turns after the winding has stabilised, the stroke at which one topology stops winning, and the specification items a supplier cannot invent on your behalf. The arithmetic is kept explicit so it can be checked against a measurement rather than accepted on authority.

Two numbers recur because they set the scale of everything else. A working gap that grows by 0.05 mm in assembly costs about 27 % of the force, and a winding that settles 70 K above ambient delivers about 61 % of its cold force at fixed voltage. Neither appears on a typical datasheet, and both are present in almost every real installation.

15 notes in this topic